Articles within this series: |
Brief introduction of Siemens' new generation SIMATICS7-1500 series PLC
S7-1500 power module configuration system and error-prone points
'Software' Botu V13, V14 application download link and authorization
S7-1500 communication module sorts, interface descriptions, parameter settings
S7-1500 signal module parameters, wiring, jumper strategy
Configure CPU parameters in TIA Portal computer software
The project created applying Botu is no longer a single file like S7-200, but a project folder is created. The name in the folder may be the project name, and you will find several files expected by the plan inside the folder.
The following picture may be the folder named 'Project 2':
Any time you have to have to copy the Portal project to another location, of course copying the complete folder just isn't a fantastic way. In data recovery free of this project is fairly long, a large variety of files will probably be generated, resulting in slow copying.
Botu Application offers project archiving and minimization functions to solve backup projects.
1. data recovery software archiving
Project archiving is really a system of compressing projects offered by Botu. It could compress the complete project into a file, and this file contains the total project. The suffix with the compressed project file name is '.zap13' or '.zap14', and the quantity around the suffix is the version variety of Botu.
Methods:
Click around the 'Project' menu in Portal Computer software and select 'Archive'.
Inside data recovery software -up dialog box, pick the archived directory
Set the archive path and name, pick the item 'TIAPortal Project Archive'.
Archived file, item two.zap13
two. Reduce the project
The file filed right after employing the project is often a compressed file. The advantage is the fact that it is straightforward to retailer. You are able to use U disk or mail to provide the project, but you should restore the project by opening the project.
Minimizing data recovery software does not compress the project file, it can only create a copy of the project, this copy only has the fundamental components of your project, so the storage space is fairly modest, and can be very easily opened via the Botu software.
The system of minimizing the project is the same as the archive project, only will need to pick the 'Minimize TIAPortal' project when picking the archive sort.
three. Restore the archived project
When we get the archived project, it really is not possible to edit the project, along with the project cannot be edited until the project is restored.
Click on the 'Project' menu inside the Portal software and pick 'Restore'.
Soon after selecting the 'Restore' item and confirming, the file to be restored is popped up, as shown inside the figure below:
Right after clicking Open, a directory for picking the project recovery pops up (this directory may be the path exactly where the project is stored following recovery)
Click 'OK' to restore the project towards the selected path
Lots of friends prefer to copy the entire project folder straight when copying the project. It is actually not advised that you do that. Additionally for the original folder is relatively massive, in the event you drop crucial files through the direct copy method, it is actually straightforward to result in it to be lost elsewhere. Open result.
Since Botu supplies a process for archiving projects, it can be better to operate in accordance with the specifications so as to make fewer mistakes.
Also towards the clear name of your project, it truly is far better to add the archive time within the back, as shown within the figure beneath.
When editing a project, develop a fantastic habit of backing up the project in time to steer clear of the circumstance of system loss right after the software program crashes.